BASIC INFO
						
					
					
	Rosemount Flow Meter 3051CFCDCS060N065032AA1WCE5M5
	The Rosemount 3051CFC Compact Orifice Plate Flow Meter is an industry-leading flow meter designed with a compact orifice plate that delivers precise flow measurements. This flow meter has been leak-tested and calibrated to reduce leak points and increases process control. Available in a range of line sizes (0.5 - 12 in. or 15 - 300 mm), the orifice plate withstands harsh process conditions and is engineered for loop control, general purpose monitoring and custody transfer applications.
	Specifications
	Warranty Up to 5-year limited warranty
	Rangedown Up to 150:1 (8:1 flow turndown)
	Measurement Range Up to 1000 inH2O (2,48 bar) differential
	Line Size 0.5 to 12 in. (15 to 300 mm)
	Output Differential pressure, scaled variable
	Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V Low Power HART®
	Process Wetted Material 316 SST
	Diagnostics Power Advisory Diagnostics, Advanced Diagnostics
	Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE®, hazardous location, see full specs for complete list of certifications
	Features
	Complete flow assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation
	General purpose orifice plate design delivers reliable and accurate flow measurement for gas, liquid and steam service
	Primary element available in 0.5 - 12 in. (15 - 300 mm) line sizes for application flexibility
	10-year stability and 8:1 flow turndown (150:1 rangedown) produce reliable measurements and application flexibility
	Local operator interface offers easy-to-use menus and built-in configuration buttons for streamlined commissioning
	Power advisory diagnostics detect electrical loop integrity issues for reduced downtime
	SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
	Rosemount 3051CFC Compact Flowmeters provide a quick, reliable installation
	between existing raised face flanges. Depending on your application needs, you can
	reduce energy loss with the Compact Annubar or minimize straight run requirements
	with the conditioning orifice.
	 
	Up to 1.8 percent of flow rate accuracy
	Available in 1/2- to 12-in. (15 to 300 mm) line sizes
	Fully assembled and leak tested for out-of-the-box installation
	Power advisory can proactively detect degraded electrical loop integrity issues.(option code DA0)
	LOI with straightforward menus and built-in configuration buttons (option code M4)
	
	 
	-----------------------------------
	Lily
	HONGKONG XIEYUAN TECH CO., LIMITED
	T: 86-027-85581877 F: 86-027-85309780 
	Mail:lily@hkxytech.com
	Ad: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan, Hubei, China
	Web: www.hkxytech.com
					 
			 
		 
	 
							 
											