Fluke 54 II B Dual Input Digital Thermometer with Data Logging
Laboratory accuracy. Wherever you go
Fluke 54 II B dual input digital thermometer can log up to 500 points of data to internal memory. Fast response and laboratory accuracy (0.05% + 0.3°C). Take contact temperature for checking motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, E, N, R, and S type thermocouple (temperature sensors).
- Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX, or AVG
- Recall function allows logged data to be easily reviewed on the meter display
- Infrared USB communication port allows data to be exported to optional FlukeView Forms® Temperature PC software for further analysis and graphing
- Data Logging up to 500 points of data with user adjustable recording interval
- Relative time clock on MIN, MAX, and AVG provides a time reference for major events
- Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
- Measures J, K, T, E, R, S, and N-type thermocouples
- Readout in °C, °F, or Kelvin (K)
- Splash and dust resistant case protected by impact absorbing holster
- User-friendly front panel is easy to set up and operate
- Sleep mode increases battery life; typical 1000-hour battery life
- Battery door allows easy battery replacement without breaking the calibration seal
- Optional ToolPak accessory allows the thermometer to hang from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation
- 3 year warranty
General Specifications | ||
Temperature accuracy | Above -100°C | J, K, T, E, and N-type: ±[0.05% + 0.3°C]1 |
R and S-type: ±[0.05% + 0.4°C]1 | ||
Below -100°C | J, K, E, and N-types: ±[0.20% + 0.3°C]1 | |
T-type: ±[0.50% + 0.3°C] | ||
Temperature | J-type | -210°C to 1200°C |
K-type | -200°C to 1372°C | |
T-type | -250°C to 400°C | |
E-type | -150°C to 1000°C | |
N-type | -200°C to 1300°C1 | |
R and S-type | 0°C to 1767°C1 | |
Temperature scale | ITS-90 | |
Applicable standards | NIST-175 | |
Display resolution | 0.1°C, 0.1 K < 1000 | |
1°C, 1 K ≥ 1000 | ||
1. Only the Fluke Models 53 II B and 54 II B thermometers are capable of measuring N, R, and S-type thermocouples. | ||
Environmental Specifications | ||
Operating temperature | -10°C to 50°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) | 0% to 90%; 0°C to 35°C | |
0% to 70%; 0°C to 50°C | ||
Safety Specifications | ||
Overvoltage category | CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 | |
Agency approvals | CE, CSA, TÜV (pending) | |
Mechanical and General Specifications | ||
Size (L x W x D) | 173 x 86 x 38 mm | |
Weight | 400 g | |
Batteries | 3 AA batteries; typical 1000-hour life |
Order information:
Fluke 572-2 High-Temperature Infrared Thermometer
Fluke 62 MAX+ Infrared Thermometer
Fluke 568 Infrared and Contact Thermometer
Fluke 64 MAX IR Thermometer
Fluke 62 MAX Infrared Thermometer
Fluke 59 MAX+ Infrared Thermometer
Fluke 59 MAX Infrared Thermometer
Fluke 568 Infrared and Contact Thermometer
Fluke 566 Infrared and Contact Thermometers
Fluke 561 Infrared and Contact Thermometer
Fluke 568 Ex Intrinsically Safe Infrared Thermometer
Fluke t3000 FC Wireless Temperature Module
Fluke 63 Mini IR Thermometer
Fluke 61 IR Thermometer
Fluke FoodPro Infrared Food Thermometer
Fluke FoodPro Plus Infrared Food Thermometer
Fluke 54 II B Dual Input Digital Thermometer with Data Logging
Fluke 53 II Single Input Digital Thermometer with Data Logging
Fluke 52 II Dual Input Digital Thermometer
Fluke 51 II Single Input Digital Thermometer